New: AI Visibility Audit for B2B software
IEC 61850 / REMOTE ENGINEERING SUPPORT

INDEPENDENT · REMOTE · FIXED SCOPE

One defined piece of substation work, taken off your desk.

SCL review and a test-case pack for one substation, GOOSE/SV capture analysis, or a pre-conformance readiness review. Remote, fixed scope, fixed date, and a written result your own tooling can triage.

Send the file and the scope The 30-minute fit check is free and happens on your own file.
01 / FOUR UNITS

Each unit has one input and one written output.

A

SCL review + test-case pack — one substation

Input: the SCD (and/or the ICD/CID set), the single-line diagram or IED list, and the intended test scope. Output: a consistency and completeness report, a machine-readable issue list, and a test-case pack written against the SCD objects. Five working days.

B

GOOSE / SV capture analysis

Input: the capture, the matching SCD, the event time, and what appeared to go wrong. Output: a message timeline, missing/duplicate/stale messages, retransmission behaviour, publisher–subscriber consistency against the SCD, VLAN and priority handling, and time-synchronisation drift. Three working days.

C

Pre-conformance readiness review

Input: the device ICD and the test list you expect to be run. Output: the gaps most likely to cause a first-pass failure, ranked, with the evidence from the file. Five working days.

D

Remote workshop — 2 × 3 hours

For one team, on your own files, with exercises prepared from those files three days beforehand and sent for review.

02 / HOW IT STARTS

Fit first, then scope, then any payment.

  1. FIT CHECK

    Thirty minutes, free, on the real file. If the task is out of scope or bigger than described, I say so before starting and the fit check is not billed.

  2. SCOPE & DATE

    Required inputs, outputs, acceptance check, exclusions, delivery date and the fixed price are agreed in writing. The price is not set before the file is seen.

  3. DELIVERY

    The written and machine-readable result, one clarification round, and one 60-minute walkthrough. Payment by bank transfer against an invoice from Mohammadreza Farsizadeh (individual; Armenian correspondence address), half to start and half on delivery.

Ownership and confidentiality

Files you send are used for that task only and deleted as agreed after handover. The report, the documentation and any change are yours, with no retainer required. If you have an NDA, say so before sending a file.

03 / HONESTY

What is not claimed here.

  • No conformance certificate, accreditation or laboratory status. Where an accredited test is required, that is stated plainly.
  • No client name, project, or past industrial project is used here as a reference.
  • No ranking, revenue or market outcome is guaranteed. The defined deliverable is fixed; the market result is not.
  • No proprietary product is sold as part of the delivery; the work is done with my own scripts and your files.

To start, send the SCD or an extract without sensitive data, the project name, the real deadline, and one sentence about what is unclear today. Do not send credentials, customer data, or files under an NDA you have not cleared.

GridSight — the desktop IEC 61850 diagnostics tool — is the analysis engine being built for this work. It is in development, it is not part of this delivery, and its status and limits are written on the product page. The GridSight page

Continue to the contact form

Prefer a direct message?

Send a short description of what you need. We can clarify the next step together.